Precision. Protection. Performance in Critical Environments.
Natrle Surgical Gloves deliver surgical-grade barrier protection with anatomical precision fit. Sterile, powder free natural rubber latex with AQL 0.65 inspection standard and chemo rated performance (ASTM D6978). Designed for high-precision veterinary surgical and emergency procedures.

Box of 50 Pairs

Case of 200 Pairs
AQL 0.65 Inspection Standard
AQL 0.65, according to the applicable product quality documentation. AQL is not a guarantee that every glove is defect-free.
Chemo Rated (ASTM D6978)
Tested and certified for safe handling of hazardous chemotherapy drugs in clinical settings.
Anatomical Precision Fit
Left/right specific design with curved fingers reduces hand fatigue during extended surgical procedures.
High Tactile Sensitivity
Thin yet durable construction provides exceptional touch sensitivity for delicate surgical maneuvers.
| Material | Natural rubber latex, sterile |
| Color | Natural (light cream) |
| Sterility | Sterile, individually wrapped pairs |
| Powdered | Powder free |
| Design | Anatomical, left/right specific |
| Cuff Type | Rolled cuff |
| Texture | Micro-textured fingertips |
| Finger Thickness | 0.17 mm ± 0.02 mm |
| Palm Thickness | 0.16 mm ± 0.02 mm |
| Cuff Thickness | 0.14 mm ± 0.02 mm |
| Minimum Length | 270 mm |
| AQL (Watertight) | 0.65 (G1) |
| Tensile Strength (Before Aging) | ≥ 24 MPa |
| Tensile Strength (After Aging) | ≥ 18 MPa |
| Ultimate Elongation (Before Aging) | ≥ 700% |
| Ultimate Elongation (After Aging) | ≥ 500% |
| Viral Penetration | Pass (ASTM F1671) |
| Shelf Life | 5 years from date of manufacture |
| Country of Origin | Malaysia |
Packaging, SKUs & Performance| Size | Palm Width ± 4mm |
|---|---|
| 5.5 | 70 mm |
| 6.0 | 76 mm |
| 6.5 | 83 mm |
| 7.0 | 89 mm |
| 7.5 | 95 mm |
| 8.0 | 102 mm |
| 8.5 | 108 mm |
| 9.0 | 114 mm |
| Property | Before Aging | After Aging |
|---|---|---|
| Tensile Strength (MPa) | ≥ 24.0 | ≥ 18.0 |
| Ultimate Elongation (%) | ≥ 700 | ≥ 500 |
Aging per ASTM D573 at 70°C for 166 ± 2 hours.
| Test | Inspection Level | AQL |
|---|---|---|
| Watertight Test | G1 | 0.65 |
| Visual Test (Major) | S4 | 2.5 |
| Visual Test (Minor) | S4 | 4.0 |
| Physical Dimension | S2 | 4.0 |
| Physical Properties | S2 | 4.0 |
Particulate Residue: ≤ 2 mg/glove (N=5)
Compliance, Chemical Resistance & SustainabilityDocumented via separate test reports.
Natrle Surgical Gloves are engineered for high-precision clinical environments where barrier integrity is non-negotiable.
AQL 0.65
Documented hole-detection standard; see applicable product quality documentation
ASTM F1671
Viral penetration barrier certified
ASTM D3577
Sterile surgical glove specification
ASTM D6978
Chemo Rated for drug handling
| Drug | Conc. | BT |
|---|---|---|
| Carboplatin | 10.0 mg/ml | > 240 min |
| Cisplatin | 1.0 mg/ml | > 240 min |
| Cyclophosphamide | 20.0 mg/ml | > 240 min |
| Doxorubicin HCl | 2.0 mg/ml | > 240 min |
| Etoposide | 20.0 mg/ml | > 240 min |
| Drug | Conc. | BT |
|---|---|---|
| Fluorouracil | 50.0 mg/ml | > 240 min |
| Gemcitabine | 38.0 mg/ml | > 240 min |
| Methotrexate | 25.0 mg/ml | > 240 min |
| Paclitaxel | 6.0 mg/ml | > 240 min |
| Vincristine Sulfate | 1.0 mg/ml | > 240 min |
| Fentanyl Citrate Injection | 100 mcg/2ml | > 240 min |
Clinical excellence and environmental responsibility in every glove.
hello@vetflex.com
natrle.com